Read a floor plan PDF, get the room-wise cooling load
LoadLens turns a floor plan PDF or a room schedule into the cooling load room by room — TR, L/s and watts, read from the room names and areas already written in your drawing. No CAD, no spreadsheet, no sign-up.
No drawing to hand? The button above opens a real plan with its rooms and its load already worked out — nothing to set up, no button to hunt for. The Start here bar inside the calculator is for your own PDF. Nothing to install, nothing to sign up for.
Your drawing is never sent to a third party — on loadlens.net it is posted to this site's own
server so it can be read faster, and it is not stored. Or run npm start and use it
entirely offline.
- Free · no sign-up
- TR · L/s · per-room W
- Editable room table
- CSV + printable report
- Works offline
How it works — three steps
From the drawing to a number you can put in a report, in a few minutes.
-
Upload the floor plan PDF
Drop one or many PDFs, a scanned sheet, or your room schedule (.csv / .tsv / .xlsx). LoadLens reads the text layer and pulls out the room name, number, level and area it finds. It works in your browser — no upload to a third party.
-
Check the rooms it found
Every room appears in an editable table. Fix a name, type the real area, set the orientation, tick Roof for the top floor and untick anything that is not air conditioned. Toilets, staircases and shafts are excluded for you.
-
Read TR / L/s and export
The summary shows total tonnes of refrigeration, supply air L/s, fresh-air L/s and ft²/TR, plus a per-room breakdown and per-level subtotals. Download the CSV or print the report to PDF.
What is in the calculator
-
Room name, area and level extraction
Reads text-layer PDFs: room tags drawn on the plan, or a room schedule table. It also imports Excel / CSV room schedules directly, and can read a scanned sheet with the optional OCR box.
-
Editable room table
Every value is yours to override — name, level, area, height, people, glass, walls, orientation.
-
Country / city design conditions
Kerala, the Gulf and more, with outdoor dry bulb and wet bulb already filled in. Or type your own. See the sourced ASHRAE 2021 design conditions for cities worldwide.
-
Per-room breakdown chart
See exactly what makes the load: glass solar, wall, roof, people, lighting, equipment, infiltration, fresh air.
-
Per-level subtotals
Ground / first / terrace level totals in TR and L/s, so each floor can be sized on its own.
-
CSV export
One row per room with all inputs and results, ready for Excel or your own sheet.
-
Printable report
A clean A4 report with design conditions, assumptions, room-wise table and the important notes.
-
Offline in the browser, or faster with Node
Works with no server at all (GitHub Pages). Run
npm startand a small Express server reads the PDF for you — same result, faster.
Who it is for
MEP / HVAC students and modellers
- Practise a real room-wise load on a real drawing, not a textbook table.
- See the size of each component — glass solar, people, fresh air — and how it changes.
- Learn what the assumptions do before they go into a live project.
Consultancies in Kerala and the Gulf
- Hot, humid design conditions (Kochi 35/28 °C, Dubai 46/29 °C) are already loaded.
- First-pass tonnes, L/s and ft²/TR in minutes, to check a tender document.
- CSV and a printable report for the file — then verify before it goes out.
What this tool does not do — please read
- A scanned drawing needs help. The best input is a text-layer PDF (exported from CAD or a drafting tool) or an Excel / CSV room schedule. LoadLens can also read a scanned or image PDF with the optional OCR box, but OCR is slow and the small area labels on a scanned drawing usually cannot be read back — for a scan, import the Excel / CSV room schedule instead.
- The load method is handbook-level. It is a simplified ASHRAE / Carrier E-20 style estimate using peak solar gain and equivalent temperature differences (ETD / CLTD), not a full hourly radiant-time-series calculation. See the method page for the exact numbers.
- Every result must be checked by a qualified HVAC engineer. Areas, heights, glass, people and ventilation rates read from a drawing are a starting point, not a design. Duct heat gain, fan heat, diversity and the local code are not included.
- It is for study and for checking. Do not issue a final equipment selection from these numbers without a proper check.